Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Obstetrics & Gynecology Science ; : 328-332, 2016.
Article in English | WPRIM | ID: wpr-81072

ABSTRACT

Female adnexal tumor of probable Wolffian origin (FATWO) is a rare disease entity that arises from the mesonephric duct system. FATWO is different than other gynecological cancers in terms of embryology. Here, we describe the case of a 52-year-old woman with malignant FATWO. The patient underwent explorative laparotomy and surgical staging after a frozen section revealed malignancy. Detailed examination of the pathologic findings were consistent with FATWO. Counseling and further testing were provided to the patient to assess the risk of germline mutation and epigenetic change. An O-6-methylguanine-DNA methyltransferase gene methylation test was positive, and all other tests were normal. This is the first study to report a case of O-6-methylguanine-DNA methyltransferase methylation with FATWO in Korea.


Subject(s)
Female , Humans , Middle Aged , Counseling , Embryology , Epigenesis, Genetic , Epigenomics , Frozen Sections , Germ-Line Mutation , Korea , Laparotomy , Methylation , Rare Diseases , Wolffian Ducts
2.
Korean Journal of Radiology ; : 746-756, 2014.
Article in English | WPRIM | ID: wpr-228632

ABSTRACT

OBJECTIVE: To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. MATERIALS AND METHODS: Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations from 0 to 210 mg/mL of iodinated contrast medium at intervals of 15 or 30 mg/mL. Image noise, tissue contrast, and beam hardening artifacts were assessed to determine the optimum dose of contrast agent and the level of monochromatic energy for DECT shoulder arthrography in terms of the lowest image noise and the least beam hardening artifacts while good tissue contrast was maintained. Material decomposition (MD) imaging for bone-iodine differentiation was qualitatively assessed. The optimized protocol was applied and evaluated in 23 patients. RESULTS: The optimal contrast dose and energy level were determined by the phantom study at 60 mg/mL and 72 keV, respectively. This optimized protocol for human study reduced the image noise and the beam-hardening artifacts by 35.9% and 44.5%, respectively. Bone-iodine differentiation by MD imaging was not affected by the iodine concentration or level of energy. CONCLUSION: Dual-energy scan with monochromatic spectral imaging mode results in reduced image noise and beam hardening artifacts.


Subject(s)
Female , Humans , Male , Middle Aged , Analysis of Variance , Artifacts , Contrast Media , Phantoms, Imaging , Shoulder Joint/pathology , Signal-To-Noise Ratio , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL